Select the use mode of the barrier.
Norm: Standard operating mode, for barriers used in a residential/industrial environment and
with normal traffic.
Parc: Park operating mode, for barriers used in parking systems. In this mode, to promote transit
of a high number of vehicles, the control unit automatically sets a specific configuration which
Mode
includes:
1) Rapid closure enabled (SCL:ON) with time reduced from 3 to 0 seconds.
2) Automatic closure enabled (TCA:ON) which with rapid closure enabled causes, during the
opening phase, immediate closure of the barrier as soon as the PHOT input is free.
3) During the closure phase, PHOT entrance activation stops the barrier, as soon as the PHOT
input is free again, the barrier starts the closure manoeuvre.
MENU
Automatic closing time. Enabled only with logic "TCA"=ON.
TCA
At the end of the set time, the control unit commands a closing maneuver .
FSTS
Adjusts the opening and closing speed of the barrier (standard speed, before the slowdown phase).
sldo
Adjusts the slowdown speed of the barrier during the opening phase* (Fig.11 -slow Open).
sldc
Adjusts the slowdown speed of the barrier during the closing phase * (Fig.12 -slow Close).
Sets the starting point of the slowdown during the opening phase (Fig.11- beginning of the slow
tsmo
Open). The value is expressed in percentage on the entire stroke.
Sets the starting point of the slowdown during the closing phase (Fig.12- beginning of the slow
tsmc
Close). The value is expressed in percentage on the entire stroke.
PMO
Adjusts the motor torque applied to the barrier during the opening phase.*
PMC
Adjusts the motor torque applied to the barrier during the closing phase.*
Adjusts the motor torque applied to the barrier during the slowdown in opening phase * (Fig.10
PSO
- Slow Open).
Adjusts the motor torque applied to the barrier during the slowdown in closing phase * (Fig.11
PSC
- Slow Close).
Adjusts the intervention threshold of the anti crushing device (Encoder) during the normal speed*.
SeaU
0:Off -1: minimum sensitivity - 99: maximum sensitivity
Adjusts the intervention threshold of the anti crushing device (Encoder) during the slowdown speed*.
SEAR
0:Off -1: minimum sensitivity - 99: maximum sensitivity
Activation time of the courtesy light contact. Value expressed in seconds. At the beginning of
tls
each maneuver the contact latches for the set time.
See the description of AUX1 parameter.
Sets a short reversion after reaching the limit switch in open position. Can be useful for facilitat-
saso
ing the manual release.
Sets a short reversion after reaching the limit switch in close position. Can be useful for facilitat-
sasc
ing the manual release.
Selects the functioning mode of the auxiliary output 1 (N.O. clean contact)
0: Open barrier light, close contact when the barrier is open, open contact when the barrier is
close, intermittent during the maneuver (fig. 14, SCA)
1: Second radio cannel of the built in receiver
2: Boom light, for controlling the LED light installed on the BOOM (EVA.LED), see also the pa-
rameter LBAR.
aux1
3: Courtesy light, the contact remains close according to the parameter TLS (fig.14 SERVICE LIGHT)
4: Photocells test, see wiring diagram in Fig.14 (PHOTOTEST)
5: Close contact with open barrier
6: Close contact with close barrier
7: Maintenance warning light. The contact closes when the number of manoeuvres set in the
Maintenance Cycle menu is reached (MACI).
* ATTENTION: A WRONG SETTING OF THESE PARAMETERS CAN BE DANGEROUS.
RESPECT THE REGULATION IN FORCE!
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has no
IbL
effect during the opening phase.
Off: condominium function disabled.
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter signal has no
ibca
effect during the TCA counting.
Off: the bloc of flat function is disabled.
24
13.3.2) PARAMETERS (PAR)
FUNCTION
13.3.3) LOGICS (LOG)
FUNZIONE
Norm - Parc (Norm)
MIN-MAX-(Default)
MEMO
1-240-(20s)
50-99-(99)
20-70-(50)
20-70-(50)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
0-99-(0%)
0-99-(0%)
1-240 (60)
0-5 (0)
0-5 (0)
0-6-(0)
ON-OFF-(Default)
MEMO
(ON)
(OFF)
(OFF)