DO
Read the Operation and Maintenance Manual.
Check all hose connections.
Use a 12 gauge cord if the cord is under 50 ft (15 m) or a 10 gauge
cord if the cord is over 50 ft (15 m).
Provide fresh air intake for the cooler and maintain a minimum
clearance of 3 ft (0.9 m) behind the cooler.
Flush new cooling media.
1.
Fill the cooler with water.
2. Switch on the pump.
3. Run the cooler without the fan running for at least 5 hours.
Make sure the cooling media is being evenly saturated by using the
control valve to adjust the water flow.
Drain and clean the cooler weekly. Remove the cooling media and
wash with a garden hose.
Use Refresh™ tablets (algae killer) and/or CTT-EC™ cooler treatment
tablets (mineral treatment). Water treatment tablets are available at
bigassfans.com.
DO NOT
Χ
DO NOT forget to dry out the cooling media before shutting down
the cooler. Turn off the pump and leave the fan running for 10 to 15
minutes.
Χ
DO NOT run the pump without filling the reservoir with water first.
Χ
DO NOT completely open the water valve. This may flood the
cooling media.
Χ
DO NOT use a water source with more than 120 PSI of water
pressure.
Χ
DO NOT operate the cooler in a sealed room. Allow for fresh air
intake and exhaust.
WWW.BIGASSFANS.COM

CHECKLIST

© 2020 DELTA T LLC
ALL RIGHTS RESERVED.
1