RT-3, RT-5x, RT-7x and RT-9x Thermal Imagers
not be seen when measurements are being
made but pressing any key will bring the
menu back up.
4. Move the joystick down/up and select which
differential temperature is to be calculated
(Point-Point, Point-Value, Point-RTC). Then
press OK.
5. Point-Point Selection:
a. Move the joystick to the right, select meas-
uring point 1 and press OK. Move the
measuring point to the live image using the
joystick and press OK.
b. Move the joystick to the right, select meas-
uring point 2 and press OK. Move the
measuring point to the live image using the
joystick and press OK.
6. Point-Value Selection:
a. Move the joystick to the right and select
measuring point 1 and press OK. Move the
measuring point in the image using the joy-
stick and press OK.
b. Move the joystick to the right and set the
value manually.
7. Point-RTC Selection:
a. Move the joystick to the right and select
measuring point 1 and press OK. Move the
measuring point in the image using the joy-
stick and press OK.
b. Move the joystick to the right and set the
value manually.
8. End measurement: Move the joystick to the
right, press End.
Activating/Disabling The
Min/Max On Area Function
1. Open Menu.
2. Move the joystick down and select Measure-
ment. Then press OK or move the joystick to
the right.
3. Move the joystick down and select Min/Max
on Area. Then press OK or move the joystick
to the right.
4. Select Min/Max on Area and press OK to ac-
tivate or disable the function.
a. Select Hot spot/Cold spot and press OK to
activate or disable the function.
b. Select Hide all and press OK to disable all
functions for the measuring range.
14

Configuration

Country Settings
The user interface language can be set.
1. Select the Country settings function.
2. Move the joystick up/down to select the de-
sired language and then press OK.
Set Time/Date
The time and date format are set automatically
based on the selected user interface language.
1. Select the Set time/date function.
2. Move the joystick to the right/left to select the
desired setting option.
3. Move the joystick up/down to set the value.
4. After setting all values, press OK.
Power-Save Options
The illumination intensity of the display can be set.
A lower intensity increases the battery life. The
time until automatic switch-off can be set.
1. Select the Power-save options function.
2. Move the joystick up/down to select the de-
sired intensity level and then press OK.

SuperResolution

SuperResolution is a technology to improve
image quality. Each time a SuperResolution
image is recorded, a sequence of images is
saved and used to calculate an image with four
times more resolution. The geometric resolution
(IFOV) is improved by a factor of 1.6. SuperReso-
lution images take longer to process, which will
be indicated in the status bar. Up to five Super-
Resolution images can be processed at one time.
To use the function, the camera should be hand-
held and the objects to be imaged should not
move.
1. Open the SuperResolution function.
2. Press OK to activate or disable the function.
Full Screen Mode
1. Select the Full screen mode function.
2. When Full Screen Mode is activated, the scale
and icon for the quick select button are hidden.
When a key is pressed, these elements are
displayed briefly.