Foreseen Operating Conditions; Assembly And Wiring Instructions - Dea 212 E Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6 OPERATING CONDITIONS
212 E control board is designed for the automation of swing gates operated by 230 V ~ motors.
This control board has been designed and tested for operation under "normal" conditions for both
residential use.
WARNING Using the product under unusual conditions not foreseen by manufacturer may cause
dangerous situations; this is the reason why all the conditions prescribed in these instructions must be
followed.
WARNING Under no circumstance must the product be used in an explosive environment or sur-
roundings that may prove corrosive and damage parts of the product.
7

ASSEMBLY AND WIRING INSTRUCTIONS

Connect to the power supply 230 V ~ 50 Hz through a multi pole switch or a different device that can
ensure multi pole disconnection from the power supply, with a contact opening of 3,5 mm. Use a cable
with a minimum section of 3 x 1,5 mm² (e.g. a H07RN-F type).
1-2
230 V
F
N
230 V ~ 50 Hz max 40 W flashing light output
3-4
2nd motor output max 500 W (5 = open, 6 = common, 7 = close)
2
5-6-7
1st motor output max 500 W (8 = open, 9 = common, 10 = close)
1
8-9-10
24 V ~ power supply output for controlled safety devices. To be used as power supply
11-13
for photocells transmitters and of safety devices when testing these latter before each
24Vsic
gate operation
24 V ~ power supply output for auxiliary circuit and uncontrolled safety devices. To
12-13
be used as power supply for any auxiliary device of photocells receivers and for safety
24Vaux
devices when testing these latter before each gate operation
WARNING 1 motor working: N.C. input end of stroke while closing. If unused, short
circuit to terminal n. 19
14
FCC
WARNING 2 motors working: unused input, short circuit to terminal n. 19
WARNING 1 motor working: N.C. input end of stroke while opening. If unused, short
circuit to terminal n. 19
15
FCA/SIC2
WARNING 2 motors working: N.C. input, external safety device. In the case of activa-
tion, it inverses the movement. If unused, short circuit to terminal n. 19
N.C. input, external safety device. In the case of activation, it inverses the movement.
16
SIC1
If unused, short circuit to terminal n. 19
N.C. photocell input, in thecase of activation while closing, it inverses the movement.
17
FOTO
If unused, short circuit to terminal n. 19
N.O. start input. If activated it opens or closes the gate. It can work in "reversal" mode
18
or "step by step" (see paragraph 8.5). It can be used also for a temporized contact
START
connection.
19
Common inputs
COM
20
Antenna signal
21
Antenna ground
8
OPERATING INSTRUCTIONS
After making all connections to the terminal board, remember to short-circuit all unused input, and power
the card.
Table 1 terminal boards connection
~
- 50 Hz power supply input (L=phase, N=neutral)
Operating instructions and warnings
only for qualified personnel
A2
A3
9
2 1 2 E

Publicité

Table des Matières
loading

Table des Matières