240 VAC POWER SUPPLY Models: MULTI POSITION SUP15-E230V1 SUP18-E230V1 VARIABLE SPEED BLOWER SUP20-E230V1 MOTOR (ECM) SUP23-E230V2 SUP27-E230V2 Caution: Do not tamper with INSTALLER / SERVICE TECHNICIAN: the unit or its controls. Call a qualified service technician. USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND...
Ask the technician installing your furnace to show 1.0 ..........SAFETY and explain to you the following items: The main disconnect switch or circuit breaker; DANGER, WARNING AND CAUTION The air filter and how to change it (check monthly and clean or replace if necessary); The words DANGER, WARNING and CAUTION are used to Before calling for service, be sure to have the identify the levels of seriousness of certain hazards.
If the static pressure is high in the supply duct because of a CONFIGURATIONS large duct system or the addition of a cooling coil, it is suggested to close down the louvers until the noise or the This furnace requires suitable ductwork. vibration is decreased to a normal level.
Refer to Figure 3 for additional details. Figure 3 : Horizontal installation ELECTRICAL SYSTEM The SUPREME furnace is completely pre-wired and all field wiring must be connected to the terminal blocks on the unit. It requires a 240 volt, 2-wire power supply.
Use flexible hangers to suspend the ducts. heat pump thermostat The SUPREME furnace is equipped with a filter frame for the blower compartment. It must be installed on the outside of one of the three sides or the bottom of the furnace. Once the location of the installation has been determined, use the four square knockouts for ease of cutting the opening.
30/90: 30 second ON delay with no airflow and 90 2.6.2. AC/HP size second OFF delay at 100% airflow profile. Used when it is desirable to allow system coils time to heat-up/cool- Select System Size Installed down in conjunction with the airflow. 0/0: No delay option.
INSTALLATION OF ACCESSORIES airflow to approximately 80% of nominal cooling mode airflow. This reduction will increase the system latent capacity until the humidity falls to a level which causes the WARNING humidistat contact to close its contacts. Electrical shock hazard. 2.7.4.
• Thermostat closes circuit R to W1 or W2. Figure 13 : Manual Furnace Controls • Furnace delivers the selected electric heat airflow and maximum heating capacity is powered starting the heating elements in sequence with a delay of 8 seconds between each.
0.82 x amps. x volts Remove the obstruction and the elements should restart Liter/s= ------------------------- after a few minutes. Diff. temperature ˚C 3.1 x amps. x volts MAINTENANCE CFM = ------------------------ Diff. temperature ˚F Preventive maintenance best avoid 3.4.1. Supply Air Temperature Rise Test unnecessary expense and inconvenience.
FURNACE INFORMATION Model: Serial number: Furnace installation date: Service telephone # - Day: Night: Dealer name and address: START-UP RESULTS Voltage: Total current consumed by the elements: Supply air temperature: Return air temperature: Supply air duct static pressure: Return air duct static pressure: Total pressure: Calculated air flow: Current consumed by the blower motor:...
Table 1 : Sequence of operation Thermostat to Control Control Mode Control Function Board 24 VAC State Electric Heat only Continous Fan Fan ON at the selected continous fan CFM (Fan switch ON) Fan OFF Fan ON at 50% of the selected Heat CFM, 1st stage of Heat ON** Themostat calls for 1st stage Heat W1 ▼...
Table 2 : Technical Specifications SPECIFICATIONS, SUP ELECTRIC FURNACE WITH ECM MOTOR SUPxx -E230V1 SUPxx -E230V2 RATINGS AND PERFORMANCE Power second stage (Kw) Power first stage (Kw) Net capacity second stage (BTU/h) 51180 61420 68240 78480 92130 Heating temperature rise, second stage heating (F) Heating temperature rise, first stage heating (F) ELECTRICAL SYSTEM Volts - Hertz - Phase...
Page 18
Table 3 : Electric furnace SUP, ECM ½ HP motor, air flow tables COOLING OR HEAT PUMP HEATING MODE (WITH HP-EFF SELECTED ? ) 24 VAC (R) input on G, Y/Y2 and O (for cooling) AC / HP SIZE CFM ? CFM ? CFM ? A/C size...
Page 19
Table 4 : Electric furnace SUP, ECM 1.0 HP motor, air flow tables COOLING OR HEAT PUMP HEAT ING MODE (WIT H HP-EFF SELECT ED ? ) 24 VAC (R) input on G, Y/Y2 and O (for cooling) AC / HP SIZE CFM ? CFM ? CFM ?
Page 20
Figure 19 : PARTS LIST, Supreme with ECM : SUPxx-E230V1 or SUPxx-E230V2 B50132A.dwg...
Table 5 : PARTS LIST, Supreme with ECM : SUPxx-E230V1 or SUPxx-E230V2 ITEM PART # DESCRIPTION COMMENTS B04115-01 HEATING ELEMENT PLATE ASSEMBLY SUP15kw (1/2 HP) Item 12 included B04116-01 HEATING ELEMENT PLATE ASSEMBLY SUP18kw (1/2 HP) Item 12 included B04116-02...
Page 23
ALIMENTATION 240 VAC Modèles: MULTI – POSITION SUP15-E230V1 MOTEUR VITESSE VARIABLE SUP18-E230V1 SUP20-E230V1 SUP23-E230V2 SUP27-E230V2 Attention : Ne pas altérer votre INSTALLATEUR / TECHNICIEN : unité ou ses contrôles. Appeler un technicien qualifié. UTILISER RENSEIGNEMENTS DANS MANUEL POUR L’INSTALLATION ET L’ENTRETIEN DE L’APPAREIL ET GARDER LE Fabriqué...
Page 24
TABLEAUX TABLE DES MATIÈRES Tableau 1 : Séquence de fonctionnement ......13 SÉCURITÉ ............. 3 Tableau 2 : Spécifications techniques........14 DANGER, MISE EN GARDE, AVERTISSEMENT . 3 REMARQUES IMPORTANTES ......3 Tableau 3 : Débits d’air (PCM) – moteur ECM ½ HP..17 RISQUE DE GEL............
Ne pas faire fonctionner cette fournaise si elle était SÉCURITÉ immergée dans l’eau. Appeler immédiatement un technicien qualifié pour vérifier les dommages et DANGER, MISE EN GARDE ET remplacer les pièces critiques qui ont été en contact AVERTISSEMENT avec l’eau. Ne pas ranger ou utiliser d’essence ou toutes autres Comprenez bien la portée des mots suivant : DANGER, MISE substances inflammables à...
DÉGAGEMENT MATÉRIAUX INSTALLATION COMBUSTIBLES Cet appareil de chauffage central est une véritable unité 2.2.1. Pour l’unité de chauffage multi-position puisqu’il peut fonctionner en débit ascendant, descendant et à l’horizontale avec le débit d’air vers la La fournaise est approuvée pour un dégagement de 0 pouce gauche ou la droite.
2.3.2. Débit descendant MISE EN GARDE Le retour d’air peut s’installer en dessous, en arrière, sur le côté droit ou sur le côté gauche de l’unité. Risque de feu Lorsque l’appareil de chauffage central est installé avec un Le dimensionnement des conducteurs doit être fait en débit descendant plancher...
2.5.2. Conduits et filtres Figure 9 : Carte de contrôle du ventilateur Les conduits doivent être dimensionnés de façon à accommoder les débits spécifiés et les pressions statiques disponibles. Utiliser les codes d’installation locaux et nationaux pouvant s’appliquer. Isoler les conduits qui traversent un espace non-chauffé. Utiliser des raccords de retour et d’alimentation flexible éviter la transmission de vibrations.
2.6.3. Type de système réchauffer/refroidir serpentin système conjonction avec le débit d’air. Sélectionner le type de système installé, climatiseur ou 0/0: Aucun délai ON/OFF. Pour la maintenance de pompe à chaleur (identifié «SYSTEM TYPE» sur la carte l’unité ou lorsqu’un thermostat est utilisé pour la de contrôle) temporisation.
«AC/HP SIZE» – Sélectionner la taille du système de Figure 12 : Branchement d’un filtre à air électronique climatisation/pompe à chaleur installé. «SYSTEM TYPE» – Sélectionner HP-EFF. «AC/HP CFM ADJUST» – Sélectionner NOM. «ON/OFF DELAY» – Sélectionner le profil 0/90. DNS-1154 Rev.
UTILISATION DES COMMANDES MANUELLES 3.3.1. Ventilation continue SUR LA FOURNAISE • Le thermostat ferme le circuit R vers G. • Ventilation et débit d’air continus. La lumière (L-1) s’allume lorsqu’il y a une demande de chauffage. Se référer au diagramme électrique. 3.3.2.
puissance de chauffage est activée en démarrant les On peut calculer approximativement le débit d’air au moyen éléments séquentiellement avec un délai de 8 secondes des données mesurées précédemment. On utilisera, pour entre chacun. ce faire, les formules suivantes : •...
Vérifier le fusible 5A de la carte de contrôle; ENTRETIEN Ajuster le thermostat au-dessus de la température ambiante. Si la fournaise ne chauffe pas, couper Les services d’entretien fréquents éviteront les bris l’alimentation électrique et appeler un technicien prématurés et les inconvénients. Faire inspecter le système qualifié.
Tableau 1 : Séquence de fonctionnement Signal 24 VAC venant État au Mode Fonction au Contrôle du thermostat contrôle Mode de chauffage avec élément électrique seulement Ventilateur ON au ''CFM'' de ventilation continue sélectionnée Ventilation continue Ventilateur OFF Ventilateur ON à 50% du ''CFM'' sélectionné, 1er stage du chauffage ON** Premier stage Chauffage électrique W1 ▼...
Tableau 2 : Spécifications techniques S P É C IFI CA TIO NS , FO UR NA IS E É LE CT RI Q U E S U P AV E C M O TE U R E CM SU Px x -E 230V1 S UP xx -E230V 2 T A U X ET P ER F OR M A N C E P ui ssan ce d eu xièm e stag e (K w )