The stove is delivered on a pallet inside a cardboard box.
First of all, remove the stove from its packaging, check
that the model is the one ordered, and make sure it has not
been damaged during transportation. Any complaints must
be made to the carrier (in writing on the accompanying
consignment note) upon receipt. Refer to the local regula-
tions in the country of use for assemby and anything else
not expressly shown. In Italy, refer to standard UNI
10683/2006, along with any regional or local health autho-
rity regulations. If the stove is to be installed in a condo-
minium, consult the administration before installing.
COMPATIBILITY WITH OTHER DEVICES
According to the regulation UNI 10683/05, the stove must
NOT be installed in the same room as extractors, type B
gas equipment or any device creating vacuum conditions.
Warning: extraction fans operating in the same room
can cause problems.

AIR INTAKE

The room of installation must have a suitable outside air
intake with a through surface area of at least 200 cm² (Ø
16), in order to replenish the burnt oxygen and ensure an
adequate combustion air flow.
Alternatively air can be drawn from the outside and conveyed
through a Ø10 pipe connected directly to the rear of the stove
*
(
) as shown in illustration 1.
To connect the pipe to the stove, eliminate the pre-carved
*
cap (
) and fit the pipe by means of a "spring wire" clamp,
then fasten the pipe.
fig. 1
INSTALLATION
*
11

SAFETY DISTANCES

- Place the stove away from flammable materials and objects;
keep a distance from the sides mobile version for 20 cm for
DIAMOND and 110 cm for DELUXE version and at least 20
cm for both the wall.
These distances are for furniture or walls which are either fire-
proof or able to withstand being raised to an environmental
temperature of 80°C without overheating to the point of cat-
ching fire. The air circulation which is created around the stove
thanks to these distances ensures efficient ventilation and
improves thermal efficiency.
- In the event the stove is to be installed on a floor made with
a flammable material, we recommend placing it on a steel
plate available as an optional.
EDILKAMIN declines any responsibility for installations not
complying with the laws in force and for misuse of the stove.
FIRE DAMPERS (with installation of the
damper on the smoke channel)
The fire damper should be easily handled and its position must
be distinguished from the outside through the adjustment
knob.
The fire damper must remain fixed in its position and must not
be able to close automatically.
The fire dumper must NOT close the flue section completely,
but it must guarantee a permanent minimum opening which
should be equal to 3 % of the section itself and in any case
equal to at least 20 cm².