CONTINUOUS : Zoom control is always performed.
This is the factory default setting.
(6) Configuring the Tracking Time Setting (AUTO
RELEASE)
Use this setting to specify a time after which auto
tracking should be forced to terminate after it starts.
The camera stops at the position it is in at the point the
tracking time is exceeded. If SELF RETURN is set, then
after the AUTO RELEASE time is up the SELF RETURN
time starts counting down and AUTO operation starts
again.
1. Move the cursor to AUTO RELEASE and then tilt the
joystick left or right to specify a tracking time.
Tilting the joystick cycles through tracking time set-
tings in the sequence shown below. (unit: sec, min)
OFF↔10S↔20S↔30S↔40S↔50S↔1MIN↔2MIN↔3MIN↔5MIN↔10MIN
The factory default setting is OFF.
(7) Configuring the Lost Target Setting (LOST
MODE)
1. Move the cursor to LOST MODE and then tilt the
joystick left or right to select the operation that
should be performed when a target is lost.
STOP
: Stops at the position where the
target is lost.
RESEACH
: When the target is lost, checks at
the current position for movement
and continues auto tracking if
movement is detected.
ZOOM-OUT
: When the target is lost, slightly
widens the view angle and checks
if movement can be newly detect-
ed. Auto tracking is continued if
movement is detected.
This is the factory default setting.
(8) Configuring the Alarm Setting (ALARM)
1. Move the cursor to ALARM and then tilt the joystick
left or right to toggle the alarm on and off.
OFF
: No alarm output
This is the factory default setting.
ON
: Alarm is output continuously during auto
tracking.
(Alarm is output to the video output cable
at 5 second intervals.)
CONT : Alarm is output once after auto tracking
continues for a preset amount of time.
Tilting the joystick cycles through settings
in the sequence shown below.
1S ↔ 10S ↔ 30S ↔ 1MIN ↔ 3MIN ↔ 5MIN
AREA : The alarm is output once only when the
target enters a preset prohibited area
while it is being tracked. For details about
prohibited areas, see the AREA SET set-
ting on this page.
Note: You need to set the alarm setting (page 44)
to output an auto tracking associated alarm from
the external alarm terminal 1 to an outside
destination. Display the setup menu, and select
ALARM for the CNT-CLS1 setting. And, if it is ON,
an alarm signal is always output regardless of the
"TIME OUT" setting.
(9) Configuring Area Settings (AREA SET)
This setting lets you mask a specific area of the screen
where you do not want movement detected. This helps
to reduce the chance of detection error. This setting
also can be used to specify areas that are alarm-
prohibited when AREA is selected for the alarm setting.
Up to a maximum of eight masked and prohibited
areas can be specified.
1. Move the cursor to AREA SET O and then press
the camera (set) button.
This will display the area setting screen.
** ZONE NUMBER 1*/8**
PAN/TILT
ZOOM/FOCUS
MODE
ZONE SCALE
SET DEL
RET TOP
2. Configure the area settings.
For details about configuring area settings, see
steps 3 through 10 under "Privacy Zone Settings"
(page 38).
3. Move the cursor to MODE, and then tilt the joystick
left or right to select an area function setting.
MASK
: Specifies that the area is detection masked.
This is the factory default setting.
ALARM : Specifies that the area is a prohibited
area.
Notes:
• Detection area masks can be used to reduce
detection error when there are moving trees,
vehicular traffic, water (which can cause reflection),
and similar items that are in the area being
monitored (on screen).
• Detection masks and prohibited areas cannot be
configured individually for each preset position.
Configured areas are applied to all preset positions.
• The prohibited area function sounds the alarm only
when something enters a prohibited area while
tracking is being done. The alarm does not sound if
the object being tracked is in the prohibited area
when auto-tracking starts.
Important: Auto tracking continues to be performed if
the target being auto tracked moves into a detection
mask area. Note that area masks do not work under
such conditions.