Igniting the Side Burner
Using the Electronic Ignition to
Ignite the Side Burner
Unlike the main burners, the side burner does not
ignite from burner 1. If one or more of the main
burners on your grill are already lit and you would like
to ignite the side burner, skip to step 3. If none of the
main burners are lit and you are only using the side
burner, start with step 1.
1) Check that the side burner control knob is in the
off
position. Check by pushing in and turning
knob clockwise (A). Also check that all main burner
control knobs are in the off
position.
Note: It is important that all burner control knobs are
in the off
position before turning on the LPG cylinder.
2) Turn gas supply on by turning cylinder valve
anti-clockwise or by moving regulator lever to the
on position depending on your regulator/cylinder
connection.
3) Open the side burner lid (B).
4) Push in and turn side burner control knob anti-
clockwise to start/high
position (C).
5) Push and hold in the igniter button (D). You will hear
the igniter clicking. Check that the side burner is lit.
The side burner flame may be difficult to see on a
bright sunny day.
6) Once side burner is ignited, continue turning the
knob anti-clockwise until you reach the desired
position.
7) If the side burner does not ignite within 4 seconds,
turn side burner control knob to the off
and wait five minutes to allow the gas to clear
before attempting to light the burner again.
Should the side burner fail to ignite using the
electronic ignition, refer to the TROUBLESHOOTING
section. There you will find instructions on igniting the
side burner with a match to help determine the exact
problem.
To Extinguish Side Burner
1) Push side burner control knob in and then turn
clockwise all the way to the off
2) Turn gas supply off at the LPG cylinder.
position
position.
D
WARNING: Open side burner lid during
m
ignition.
WARNING: Do not lean over side burner while
m
igniting or cooking.
WARNING: If ignition does not occur within
m
four seconds of attempting to light the side
burner, turn the burner control knob to
the off position. Wait five minutes to allow
accumulated gas to dissipate, and then repeat
the lighting procedure.