The Klein Tools Distance Meter determines the length of a particular cable
by measuring the total capacitance of the cable attached to the unit and
comparing that to a preset or user defi ned capacitance per foot variable.
The Klein Tools Distance Meter has two alligator clip leads, an RJ-style
twisted pair plug and a coaxial F-connector jack for input into the meter.
The unit comes pre-programmed with nominal length constants for the
following cables:
RG-59 coaxial
RG-6 coaxial
RG-11 coaxial
Cat3 twisted pair
Cat5e twisted pair
Cat6 twisted pair
User mode allows the user to adjust the capacitance per foot constant,
based on the cable that needs to be tested.
The Klein Tools Distance Meter is powered by a standard 9V battery.
• Dimensions: 4.9" x 2.7" x 1.4" (12.3 x 6.9 x 3.5 cm)
• Weight: 7.5 oz. (213 g) with battery
• Operating Temperature: 0°C / 32°F to 50°C / 122°F
• Storage Temperature: -20°C / -4°F to 60°C / 140°F
• Humidity: 10% to 90%, non-condensing
• Fault Volt Tolerance: Reports voltage present up to 20 volts AC or DC
• Battery Life: 9V Alkaline Battery, typical
• Active: 425 hours
• Standby: 4 years
• Length Measurement
• Method: Capacitance
• Resolution: 1 ft (0.3 meter)
• Length Constant Range: 10 to 40pF/ft (33 to 132pF/meter)
• Accuracy (with known length constant):
+/-5% plus +/-1ft (+/-5% plus +/-0.3 m)
• Maximum Range: 1500 ft / 450m on most cables
• To replace the battery, lightly pry off the bottom rubber cover,
and disconnect the leads.
• The device will turn itself off after fi ve minutes of non-use.
• The Battery Icon will fl ash if voltage drops below 6V, and turn
unit off after voltage drops below 5V.