Fault Indications; Causes And Rectification Of Faults - Caso Germany IMCG25 Mode D'emploi Original

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
Attention
► Improperly performed repairs can cause considerable dangers for the user and damages
to the device.

14.2 Fault indications

In the event of a fault, an error code will appear in the display; it describes the cause of the
fault.
Error code
E01
Excessive temperature within cooking chamber
The overheating cut-out terminated the current program.
Press the Pause/Cancel button to acknowledge this fault.
The device can be re-activated after the cool down phase.
E02
Technical error
A technical error has occurred. Press the Pause/Cancel button to
acknowledge this fault. Please contact our Customer Service.
E03
Sensor fault
The device has detected an error on a sensor and has terminated the
current programme. Press the Pause/Cancel button to acknowledge this
fault.
► If error messages continue to appear after an extended waiting period and restarting the
device, then the device will need to be sent to Customer Service to be inspected.

14.3 Causes and rectification of faults

The following table assists in localizing and rectifying minor faults.
Error
The selected program will not
start.
The turntable turns jerkily.
Food is not sufficiently
defrosted, warmed up or
cooked after preset time has
elapsed.
caso IMCG25
Description
Please note
Possible cause
Device door is not closed
Power plug is not plugged in
Fuse is not activated
Dirt between the turntable and
the base of cooking camber
Dirt on rolling ring
Cooking vessel too large
Incorrectly selected time or
power level
Action
Close device door
Plug in mains plug!
Activate fuse
Remove dirt
Use different cooking vessel
Re-set time and power level
Repeat process