Safety / Warranty
DESCRIPTION
This Pedestal Sump Pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-
type power cord. Sleeve bearings on motor shaft
never need lubrication. Automatic reset thermal
protection.
NOTICE: This unit is not designed for applications
involving salt water or brine! Use with salt water or
brine will void warranty.
SPECIFICATIONS
Power supply required ........................115 V, 60 Hz
Horsepower ........................................................1/3
Motor duty .............................................Intermittent
Liquid Temp. Range.......................0-21°C (32-70°F)
Individual Branch Circuit
Required GFCI Class A .....................................15 A
Motor full load (maximum)..............................3.5 A
Discharge..............................................1-1/4" FNPT
PUMP CAPACITY
Head in feet
0
5
Head in metres
0
1.5
Litres/minute
220
189
Gallons/minute
58
50
Mastercraft warrants that the products specified in this warranty are free from defects in
material or workmanship.
If within one (1) year from the date of the original consumer purchase, this pump shall
prove to be defective, it shall be repaired or replaced subject to the terms and condi-
tions set forth below.
General Terms and Conditions
This warranty shall not apply to acts of God, nor shall it apply to products which have
been subject to negligence, abuse, accident, misapplication, tampering, alteration; nor
due to improper installation, operation, maintenance or storage; nor to other than nor-
mal application, use or service, including but not limited to, operational failures caused
by corrosion, rust or other foreign materials in the system, or operation at pressures in
excess of recommended maximums as set forth in the owner's manual.
Requests for service under this warranty shall be made by returning the product to the
retail outlet as soon as possible after the discovery of any defect. We will subsequently
take corrective action as promptly as reasonably possible.
This warranty sets forth our sole obligation and the purchaser's exclusive remedy for
defective products.
GENERAL SAFETY
Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump's capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from func-
tioning normally. To prevent possible water damage
due to flooding, consult your retailer about a sec-
ondary AC sump pump, a DC backup sump pump,
and/or a high water alarm. See the "Troubleshooting
Chart" in this manual for information about com-
mon sump pump problems and remedies.
1. Know the pump application, limitations, and
potential hazards.
damage or death. Do not use in explosive
atmospheres. Pump water only with this pump.
reduce the risk of electrical shock, pull the plug
10
15
20
before servicing. Do not plug in or unplug the
3.1
4.6
6.1
pump while standing on a wet floor or in
155
102
0
water. If your basement has water or moisture
41
27
0
on the floor, do not walk on wet area until all
power has been turned off. If shut-off box is in
basement, call electric company or hydro
authority to shut-off service to the house, or
call your local fire department for instructions.
Failure to follow this warning can result in fatal
electrical shock.
2. Disconnect power to pump before servicing.
Limited Warranty
CONSUMER HOTLINE: 1 -877-455-5508
2
Risk of fire or explosion. Can
cause severe injury, property
Risk of electrical shock. Can
burn or cause death. To