TROUBLESHOOTING
PROBLEM
Low heat
1. Low heat is found in natural
with the knob
gas models.
in "HIGH"
2. Ports are blocked.
position.
3. LP tank has run out.
The propane regulator assembly
incorporates an excess flow device
designed to supply the grill with
Low heat,
sufficient gas flow. Rapid changes in
LP gas.
pressure can trigger the excess flow
device, providing a low flame and
low temperature.
Gas pressure is significantly affected
Low heat,
by gas line and length of gas line
natural gas.
from house gas line.
1. No power supply.
2. Damaged wiring or loose
LED control
connection.
panel lights
3. Wiring not attached to control
do not light
panel switch.
up.
4. Defective switch.
5. Defective LEDs.
POSSIBLE CAUSE
CORRECTIVE ACTION
1. This model is set for 7 in. natural gas
usage. Please check your natural gas
supply system to have correct gas
pressure. Regulator is not needed for
NG model.
Check the orifice if you installed NG
nozzles. Conversion kit provides the
following nozzles:
Burner
Main Burner
Side Burner
2. Clear ports of any obstructions.
3. Refill the LP tank.
Please follow these instructions:
1. Make sure all burners are "OFF".
2. Open the tank valve and wait 5
minutes.
3. Light the burner one at a time following
the lighting instructions listed on the
door liner and Page 27.
Check your gas line and make corrections
by following the chart below:
From House to Grill
Distance
Up to 25 ft.
26 – 50 ft.
51 – 100 ft.
Over 101 ft.
1. Check power supply and make sure it is
properly plugged in.
2. Check all wiring connections between
the battery box and the LED. Also
check the connections between the
LEDs on the control panel.
3. Check the connection between the LED
and the LED switch.
4. Replace the switch.
5. Replace the LED.
29
Orifice Size
Φ1.45mm
Φ1.45mm
Tubing Size
3/8 in. DIA
1/2 in. DIA
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.
3/4 in. DIA