NATURAL GAS CONVERSION
21. Remove the 3 main burner control
knobs by grasping and pulling out. Insert
the supplied slotted screwdriver (FF) into
the hole of each main burner control
valve stem as shown. Rotate the stem
counterclockwise (to the left) as far as it
will go. The stem will now be set in the
NG position.
Reattach the control knobs.
Hardware Used
Slotted
FF
screwdriver
22. Use the 17 x 19 mm wrench (EE) to
remove the LP hose and regulator from
the manifold. Then attach the NG hose
(sold separately) and tighten up with the
wrench.
Hardware Used
17 x 19 mm Wrench
EE
10 ft. Natural Gas Hose
(sold separately)
Leak Check
When checking for gas leaks, do not use an open flame. Use a soapy water solution and apply it
to the pipe joints and fittings with a brush and check for bubbles. Check flexible hoses for cuts and
wear that may affect the safe operation of the grill. Only use original equipment replacement
hoses. Use only replacement hose assemblies specified by manufacturer.
21.1
21.2
x 1
22
x 1
x 1
17
1
3
LP hose & Regulator
10 ft. Natural Gas Hose
2