Operating instructions

Forced operation

Operation procedures when the remote control can't be used.
The operation will be started if the ON/OFF button is pressed.
If you want to stop operation, re-press the button.
Forced Operation
Button
Room Temp. ≥ 24°C(75.2°F)
Operating mode
Indoor FAN Speed
Setting Temperature

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound
1 "beep".
If you want to stop the operation, re-press the button.
20 Air Conditioner
21°C(69.8°F) ≤ Room Temp. < 24°C(75.2°F)
Cooling
High
22°C(72°F)
[Ceiling Cassette Type]
Healthy Dehumidification
High
23°C(74°F)
Room Temp. < 21°C(69.8°F)
Heating
High
24°C(76°F)