Spare Parts - Hansgrohe Sanibel 5001 A18 Mode D'emploi / Instructions De Montage

Mitigeur thermostatique
Masquer les pouces Voir aussi pour Sanibel 5001 A18:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
(see page 13)

Spare parts

(see page 16)
Special accessories (see page 16)
(order as an extra)
Extension Set 22 mm (when wall is not deep
enough). #13593000
extension 25 mm
#13595000
tile-matching-disk
#95521000
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not possible
Safety stop button not operating
Diverter stiff
Diverter leaking
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking - Clean backflow preventers, ex-
- Thermostat has not been adjusted
- Hot water temperature too low
- Temperature regulator dirty or calci-
fied
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Spring defective
- Button calcified
- Diverter defective
- Dirt or sedimentation on valve seat.
Assembly see page 8
Cleaning
(see page 15)
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filter in front of the mixer and
on the MTC-thermo cartridge
- Clean filter seal between shower
and hose
change if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 65 ºC
- Clean temperature regulator, ex-
change if necessary
- Install function block turned through
180º
- Clean spring and/or button, ex-
change if necessary
- Exchange diverter
- Clean valve seat or exchange
diverter
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sanibel 14732000

Table des Matières