OBJ_BUCH-308-003.book Page 13 Monday, February 4, 2013 4:06 PM
Digital Detector
Operating temperature
Storage temperature
Relative air humidity, max.
Battery
Rechargeable battery
Operating lifetime (alkali-manganese batteries)
approx.
Weight according to EPTA-Procedure 01/2003
* depends on material and size of objects as well as material and condition of structure
** less scanning depth for wires/conductors that are not "live"
In terms of accuracy, the measuring result can be inferior in case of unfavour-
able surface quality of the base material.
Assembly
Inserting/Replacing the Battery
Using alkali-manganese or rechargeable batteries is recommended for
operation of the measuring tool.
To open the battery lid 6, press the latch 7 in the direction of the arrow
and fold the battery lid downward. Insert the battery provided. Pay atten-
tion that the polarity is correct.
When the battery low indicator a lights up on the display, measuring is
still possible for approx. 1 hour when using alkali-manganese batteries
(lower battery service life for rechargeable batteries). When the battery
low indicator a flashes, measuring is possible for approx. 10 minutes.
When the battery low indicator a and the illuminated ring 1 (red) flash,
measuring is no longer possible and the battery/rechargeable battery
must be replaced.
Remove the battery/rechargeable battery from the measuring
tool when not using it for longer periods. When storing for longer pe-
riods, the batteries/rechargeable batteries can corrode or discharge
themselves.
Bosch Power Tools
English | 13
PDO 6
–10 °C...+50 °C
–20 °C...+70 °C
80 %
1 x 9 V 6LR61
1 x 9 V 6F22
6 h
0.2 kg
1 619 929 L93 | (4.2.13)