R E P L AC I N G T H E B A L L A S T
CAUTION:
1. Disconnect (unplug) power cord from unit.
Always follow OHSA electrical lockout safety requirements
to prevent Accidental release of energy during service or
maintenance activities.
3. Disconnect all ballast wiring by pressing down on connector
tabs and pulling wire straight out.
5. Place new ballast into original location and secure
using the two (2) nuts removed in step 4.
14
Disconnect power at the breaker or fuse panel before servicing
unit. Always follow OSHA lockout procedures to prevent accidental
exposure to electrical energy.
WARNING:
UV Light in operation. Disconnect unit from power cord
before servicing. Failure to follow warnings may result in
severe eye damage.
Power
Cord
2. Open the ballast housing by removing
the four (4) screws then removing
the cover.
4. Remove the two (2) nuts securing ballast to
the case. Remove the ballast.