The image shows the device with all its functions enabled. Check on the Installer Manual how to enable the functions.
The complete manuals are available on the website: www.bticino.com
1 -
7" (Touch screen) display
2 -
OFF key
3 -
App:
touch to display the information page where you
find a QR code that allows the download of the
DOOR ENTRY app to interact with your device
4 -
Date and time
5 -
Wi-Fi Connection
6 -
Device/app association and enabled/disabled
forwarding of call
7 -
Bell exclusion
8 -
Office activation
9 -
Microphone
10 -
Answering machine activation
11 -
Quick actions
12 -
Tactile guides for the blinds
13 -
Connection key:
The green LED flashes to indicate an incoming call
The green LED comes on steady to indicate that there
is an active call
14 -
Auto-switching on/Cycling:
The red LED turns on when the key is pressed
15 -
Favorites Key:
The red LED turns on when the key is pressed
(Basic configuration = STAIRCASE LIGHT. For
a different configuration refer to the physical
configuration table in the following pages.)
16 -
Door lock release key:
The red LED turns on when the key is pressed
17 -
Wi-Fi Status:
Red LED flashing = Wi-Fi is active but not connected
to a network
LED off = disabled or properly functioning Wi-Fi
Green LED fixed = the Classe 300X is exchanging
data with the DOOR ENTRY app
(forwarding of call, auto-switching on,
configuration)
Note: When the DOOR ENTRY is connected to the
system (e.g. answer a call, display an Entrance Panel,
etc.), no operations can be made, with the exception of
the door lock release key and Favorite Key (configured
for the Staircase Light or Door Lock Direct Control
functions) that continue to operate.
18 -
Message status:
Red LED flashing = new unread note/s or message/s
in the answering machine
19 -
Bell exclusion Status:
Red LED on = Call bell disabled
20 -
Functions (only the icons for the configured
functions are displayed)
21 -
Configurator seat (See "Configurator Functions")
22 -
Configurator J1: remove if the additional power
supply is present (clamp 1 and 2)
23 -
J2 configurator: for correct operation do not remove
24 -
Line termination ON/OFF micro-switch
25 -
Mini USB socket for device Firmware update
26 -
Loudspeaker
27 -
Additional power supply clamps (1 - 2)
28 -
2 WIRE SCS/BUS connection clamps
29 -
Clamps (
) for the connection of an external call
to the floor pushbutton
30 -
Additional bell connection clamps (1 - 5M) Point-to-
Point connections are required on the clamps of the
additional bells
Video Kit