the terminal board.
6
Mount the monitor on the bracket by using the upper hooks and pivoting it till blocking the monitor by
the automatic fi xing hook . In order to take it off from the bracket, press the hook as shown in the picture
(fi g.1) and make the reverse movement.
CONNECTIONS
On the bracket there is a terminal board enabling the wiring of the following signals:
BUS:
2 couple of connectors for non-polarized bus connection
P, P:
couple of connectors for call at fl oor connection
S+, S-:
couple of connectors for additional ringer connection
BRACKET CONFIGURATION ( fi g.5)
USER:
user code
Set a number from 0 to 31 as shown in the following picture and according to the following instructions:
♦
in the system there should not be different apartments with the same user code;
♦
in case of monitors in parallel in the same apartment, they must have the same user code;
♦
the user codes of the same COLUMN must be consecutive.
ON
User
DER
USER
0
1 2 3 4 5
ON
ON
ON
User
4
1 2 3 4 5
1
2
1
2
3
4 5
ON
User
8
1 2 3 4 5
ON
User
12
1 2 3 4 5
ON
User
16
1 2 3 4 5
ON
User
20
1 2 3 4 5
ON
User
24
1 2 3 4 5
ON
User
28
1 2 3 4 5
DER:
Apartment extension code
Set a number between 0 and 3 as shown in the picture and according to the following instructions:
♦
if there is an only monitor in the apartment, the extension code should be set as 0;
♦
in apartments, it is possible to connect till 4 monitors in parallel, all of them with the same user code, but
with different extensions codes
The extension code identifi es the single indoor stations of the same user. This enables to do intercommunicating
calls addressed to the single extension in the same apartment.
12
ON
ON
ON
User
User
1
2
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
ON
ON
ON
User
User
5
6
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
ON
ON
ON
User
User
9
10
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
ON
ON
ON
User
User
13
14
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
ON
ON
ON
User
User
17
18
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
ON
ON
ON
User
User
21
22
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
ON
ON
ON
User
User
25
26
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
ON
ON
ON
User
User
29
30
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
In case of intercommunicating calls to different fl ats, in case of calls coming from outdoor sets and in case of
call at fl oor, all the user monitors always ring. It is also necessary to consider the following information:
♦
0 and 1 extensions, at call reception, ring immediately; 2 and 3 extensions ring following;
♦
if the case of a call comes from a videophone outdoor station, the monitor whose bracket is set as 0
extension, turns on; monitors connected to the other brackets set with the same user address, but with
other extensions, are able to turn on entering the 0 extension monitor, by pressing the "_" button ("video
transfer" function); the transfer is the cause of the power down of the monitor, which was previously turn
on.
DER
USER
ON
ON
1
2
1
2
3
4 5
STANDARD SETTINGS
AV1423/011 Bfast brackets, are produced with the following confi gurations:
User
3
User
7
User
Selettore impedenza
11
Impedence selector
Sèlecteur d'impédance
User
15
PROGRAMMING OF THE IMPEDANCE SELECTOR
User
19
For the correct positioning of the impedance selector please refer to the instruction manual of the Bfast video
group ref. AV4005/001
User
23
MONITOR INTERCOMMUNICATING FUNCTION
User
ALL THE PROGRAMMING OPERATIONS can be done only when the system is properly installed, wired and
27
powered
In the B-Fast system it is possible to set "
User
31
function.
A button can be set to call another system user or to call a monitor of the same user, but set as another
extension. In the fi rst case, all monitors of the user called ring, in the second case only the monitor of the
extension specifi ed during the programming, rings.
012175868.00
012175868.00
DER
ON
ON
ON
EXTENSION
EXTENSION
1
0
1 2
1 2
1 2
USER
DER
ON
ON
1
2
1
2
3
4 5
H
L
•
", "A" e "B" monitors buttons to have the intercommunicating call
ON
EXTENSION
EXTENSION
3
1 2
USER = 31
DER
= 0
SI
= L
13