installation manual
installation manuEl
Eacp105E
GalEo
Illuminated RF Keypad
Electronic control panel for two 230Vac motors
3] installing
1) Depending on the type of the gates, locate the best position for the appliance, close to the gate, safe from
shocks and tampering, high enough from the ground, safe from water and easily accessible for maintenance
operations.
2) Unscrew the 4 screws of the cover and verify the electronic card integrity. (Fig. 2).
3) Trace the 4 fixing points using the container as template mark or making reference to the distances shown on
Fig. 1
4) Drill 4 holes Ø6 mm for the plugs and fasten the box with 4 x M4 screws.
5) Insert the cable holders ( if provided ) throught the pre-cuted holes and pass the cables, keeping the mains
cables and low voltage cables seperated .
6) If not provided with the appliance, connect an all-pole 10A thermal breaker switch with contact opening distance
of 3 mm or greater.
Make sure that a differential switch with threshold of 0.03 A is fitted upstream of the system.
7) Make the connections with reference to paragraph 7.
4] Technical specifications
Parameter
Power supply
Max motor power
Power for accessories
Automatic reclosing time
Working time
Courtesy light time
Memory for S/N security codes
Security protocol
Frequency
Operating temperature
Enclosure protection
Value
230 Vac +/- 10% / 50 Hz
550 W
12/24 Vac - 250 mA
5 - 120 Sec.
3 - 120 Sec.
180 Sec.
260
Keeloq Hopping code
433,92 MHz
-20 / +70°C
IP55
En
3
erone.com