installation manuEl
installation manual
Eacp105E
GalEo
Illuminated RF Keypad
Electronic control panel for two 230Vac motors
9] dip-switch settings
Function
Automatic
1
closing
Condominium /
2
step-by-step
3
Not used
4
Opening Jolt
Contact safety
5
in opening
Flashing
6
function
7
Slow down
Periodic closing
8
command for
security
NOTES
Safety edge, connected on terminals 15-17 - This contact protects opening and closing.
DIP 5 ON: When there is an obstacle, the motors stop and reverse for 2 sec.
DIP 5 OFF: When there is an obstacle motors STOP.
In both cases after the disengagement resumes the opening.
Photocells, connected on terminals 16-17 - This contact protects only in closing : when there is an
obstacle the motors STOP;
Emergency Stop connected on terminals 21-23 - The contact, if open, will cause the immediate stop of
the automation in any situation.
FLASHING LIGHT
If Dip6=ON then:
IN OPENING: blinking slow
IN CLOSING: blinking fast
IN PAUSE: steady light
PHOTOCELL ENGAGED: Turn off
Dip-switch
Pos
ON
Automatic closing activated
OFF
Automatic closing disabled
ON
During opening does not accept further commands
OFF
Command : OPEN/STOP/CLOSE/STOP
ON
Not used
OFF
Not used
ON
Opening jolt enabled
OFF
Opening jolt disabled
NC contacts (15-17), stop & invert for 2 sec on opening, stop & invert
ON
the direction on closing
NC contacts (15-17) stop the movement on opening, stops & inverts
OFF
on closing
ON
Warning light blinking
OFF
Warning light fixed
ON
slow down mode at the end of each manouvre ( opening and closing )
OFF
No slow down : full torque
Every 180 min, the panel gives a closing command, avoiding any
ON
gate-opened situation
OFF
Function disabled
Description