installation manuEl
installation manual
Eacp105E
GalEo
Illuminated RF Keypad
Electronic control panel for two 230Vac motors
8] legenda connections
Terminals
1 - 2
230 V~
3 - 4
230 V~
3 - 5
230 V~
6 - 7 - 8
230 V~
9 - 10 - 11
230 V~
12 - 14
NC
13 - 14
NC
15 - 17
NC
16 - 17
NC
19 - 18
NC
20 - 18
NC
21 - 23
NC
22 - 23
NO
24 - 23
NO
25 - 27
24 V~
26 - 27
12 V~
28 - 29
12 V=
30 - 31
50 Ohm
(*) : short if not used
6
erone.com
Type
Input Line L-N
Output flashing lamp
Output courtesy light
Input MOTOR 1 : 6,7 Opening / Closing - 8 Common
Input MOTOR 2 : 9,10 Opening / Closing - 11 Common
Open limit switch Motor 2 (*)
Close limit switch Motor 2 (*)
Contact safety Bar ( reopen photocell ) (*)
Contact Close photocell (*)
Close limit switch Motor 1 (*)
Open limit switch Motor 1 (*)
STOP Command (*)
Pedestrian Open
START Command ( open / stop / close / stop )
Power supply photocells + accessories 24 V~ / 250 mA
Power supply photocells + accessories 12 V~ / 250 mA
Power supply Electrolock
Input antenna - Cable RG58 ( 30 GND, 31 SIGNAL)
Description