Electronic control panel for two 230Vac motors
10a] double gates programming
The programming starts with the gate closed. The first operation must be the opening: if the gates close, invert
the connection of the motor wires on the terminals.The programming of the gates will be done using the buttons
PG1 for gate 1 and PG2 for gate 2.To enter the programming press P2 for 2 sec LED L3 lights up.
2 sec.
p2
pG1
press pG1 : gate 1 starts
the slow down (*)
pG1
press pG2 : gate 2 starts
the slow down (*)
pG2
press pG1 :
gate 1 stops
pG1
press pG2 :
gate 2 stops
pG2
8
erone.com
l3
press pG1 :
gate 1 starts
Wait for leaves
staggering
press pG2 :
gate 2 starts
pG2
press pG2 :
gate 2 starts
closing
Wait for leaves
staggering
press pG1 :
gate 1 starts
closing
press pG2 : gate 2
starts the slow down
pG2
(*)
press pG1 : gate 1
starts the slow down
pG1
(*)
press pG2 :
gate 2 stops
pG2
press pG1 :
gate 1 stops
pG1
End of the procedure