1.6.
Cleaning the flue gas passes - annual
maintenance
First pull the stove away from the wall so as to create
enough room to work at the back.
To clean the flue gas passes, proceed as follows:
Disconnect the flue baffle (1) from the guide by lifting it.
Draw the right cladding (2) down out of the guide and
place it down in the ash space. Then the flue baffle can
be removed and the upper part of the combustion
chamber can be cleaned. (See Figure 4a).
Figure 4a: Removing the flue baffle
Then remove the right side wall. This is fixed with
screws (1) at the back and at the front with 3 connectors.
Remove the screws from the back and pull the side wall
off sideways. (See Figure 4b).
1.7.

Cleaning the induced draught housing and fan

This housing is made accessible for cleaning by undoing
the 4 nuts shown in Figure 5. (See arrows).
Remove the induced draught motor by pulling it out.
Now clean the flue gas passes, the induced draught fan
and the flue tubes with a brush and an ash vacuum
cleaner.
Then reassemble the components in reverse order.
Make sure that the seal is seated in the right position
again. It is essential to replace defective seals.
Make sure of the electrical connections on the fan motor
and their correct positions.
Figure 5: Induced draught fan
1 = Screw
2 = Blower motor
3 = Seal
5