Keep choke lever in "CHOKE" position for only 1
pull of the recoil starter. After first pull, move
choke lever to the "RUN" position for up to the
next 3 pulls of the recoil starter. Too much
choke leads to sparkplug fouling/engine
flooding due to the lack of incoming air. This
will cause the engine not to start.
If engine starts after 3 pulls but fails to run, or if
unit shuts down during operation, make sure
unit is on a level surface and check for proper
oil level in crankcase. This unit may be equipped
with a low oil protection device. If so, oil must
be at proper level for engine to start.

Connecting Electrical Loads

This unit has been pretested and adjusted to
handle its full capacity. Before starting the
generator, disconnect all load. Apply load only
after generator is running. Voltage is regulated
via the engine speed adjusted at the factory for
correct output. Readjusting will void warranty.
CAUTION
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the amperage
rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
1.Let engine stabilize and warm up for a few
minutes after starting.
2.Ensure circuit breaker on control panel is in
on position.
3.Plug in and turn on the desired 120 Volt AC,
single phase, 60Hz electrical loads. It is
better to attach the item with largest load first.
English
Connecting a generator to your electric utility
company's power lines or to another power
source may be against the law. In addition this
action, if done incorrectly, could damage your
generator and appliances and could cause
serious injury or even death to you or a utility
worker who may be working on nearby power
lines. If you plan to run a portable electric
generator during an outage, please notify your
electric utility company immediately and
remember to plug your appliances directly into
the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company
power lines. You are responsible for ensuring
that your generator's electricity does not feed
back into the electric utility power lines.
If the generator will be connected to a building
electrical system, consult your local utility
company or a qualified electrician. Connections
must isolate generator power from utility
power and must comply with all applicable laws
and codes.

Economy Control Switch

The Economy Control switch can be activated in
order to minimize fuel consumption and noise
while operating the unit during times of reduced
electrical output, allowing the engine speed to
idle during periods of non-use. The engine speed
returns to normal when an electrical load is
connected. When the economy switch is off, the
engine runs at normal speed continuously.
WARNING
For periods of high electrical load or momentary
fluctuations, the Economy Control Switch should
be turned OFF.
Page 16