17. Light Kit LED Driver Replacement
17.2
Remove the Two Knurled Knobs and Lockwashers
from the Threaded Studs. Retain the Hardware for
future reinstallation (Figure 40).
Slide the Ceiling Cover downward to rest on top the
Motor Housing.
17.3
Removal of the Ceiling Fan Wires, See Section 7,
Reverse Steps 7.4 through 7.1.
Disconnect the Wire Connector from the Fan Motor
Black Wire and Supply Black Wire (Figure 41)
Disconnect the Wire Connector from the Fan Motor
White Wire and the Supply White Wire (Figure 41).
Disconnect the Wire Connector from the Hanger Ball,
Hanger Bracket and Supply Green Wires (Figure 41).
Retain all Hardware for future reinstallation.
17.4
Carefully remove the Ceiling Fan (hanger ball/downrod)
from the Hanger Bracket (Figure 42).
Place the Ceiling Fan, Downrod facing up, onto a
secure solid surface in preparation of the Driver
replacement.
NOTE: Be very careful not to bend the blade
assemblies while removing the ceiling fan.
Figure 40
SUPPLY, HANGER BRACKET, &
HANGER BALL GREEN WIRES
Figure 41
NOTE: SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.
Figure 42
28
(Continued)
CEILING
COVER
THREADED
STUDS (2)
LOCKWASHERS (2)
KNURLED
KNOBS (2)
SUPPLY & FAN
WHITE WIRES
SUPPLY &
FAN BLACK
WIRES
LISTED WIRE
CONNECTOR
OUTLET
BOX
HANGER
BRACKET
HANGER BALL/
DOWNROD
ASSEMBLY
ETL Model No.: CF860