Luminance Brands KATHY IRELAND HOME LURAY ECO CF860BQ00 Mode D'emploi page 14

Ventilateur de plafond de 60 po pour environnement humide
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Optional Installation No-Light Plate Assembly
6.3
Disengage the Fan Motor Assembly 2-Pin Wire
Connector from the 2-Pin Wire Connector of the Light
Kit Assembly (Figure 23).
Store Light Kit Assembly in a safe location for future
installation.
Reinstall the #6-32 x .375" Pan Head Screw into the
Light Kit Adapter.
Securely tighten the Three #6-32 x .375" Pan Head
Screws.
A spare Light Kit Assembly #6-32 x .375" Pan Head
Screw is in the parts bag, if needed.
6.4
Carefully tuck all the Wires and Connector into the Light
Kit Adapter.
Place the No-Light Plate into the opening of the Light Kit
Adapter, aligning the Three Flat Areas on the top edge
of the No-Light Plate with the Three Raised Dimples on
the Light Kit Adapter and turn the Plate clockwise until it
stops (Figure 24).
NOTE: The no-light plate is equipped with an
interference device that will not allow it to be
installed if the light kit assembly is not removed.
NOTE: Periodically check that the no-light plate is
seated fully clockwise in Light Kit Adapter.
(Continued)
REINSTALL LIGHT
KIT ADAPTER PAN
HEAD SCREW
FAN MOTOR ASSEMBLY
2-PIN CONNECTOR
LIGHT KIT ASSEMBLY
2-PIN CONNECTOR
Figure 23
Figure 24
14
NO-LIGHT PLATE
INTERFERENCE DEVICE
FLAT AREA OF NO-LIGHT
PLATE (3)
ROTATE CLOCKWISE
LIGHT KIT
ADAPTER
RAISED
DIMPLES (3)
NO-LIGHT PLATE
ETL Model No.: CF860

Publicité

Table des Matières
loading

Table des Matières