Operation; How To Stop The Machine - Omcan Santos 68 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation

Using:
1. Start the machine by operating the On button (11).
2. Place the recipient under the bowl spout (4).
3. Introduce the fruits or vegetables into the cover feed channel (2) and push them onto the rotating grater
with the fruit plunger (3).
4. Continue this operation until the juice recipient is full or all the fruit and vegetables to be processed have
been used. Also keep an eye on the level of pulp in the pulp container (6).

HOW TO STOP THE MACHINE

The appliance is stopped:
1. By pushing the Off button (12).
2. Or by turning the clamping handle (1) from the front to the back.
3. Or by unplugging the mains cord plug (10).
Maintenance
Cleaning:
Handle the basket assembly (5) carefully so as not to put it out of shape thus preventing the machine from
working properly.
To clean the basket assembly (5), it is recommended to use the brush (26) supplied with the machine,
for proper cleaning of filter sieve holes and the grater teeth (24). Fig. 17. Do not use abrasive sponge for
cleaning the basket.
Cleaning will be easier if you do not wait for the food remains to dry in the bowl, basket and cover.
Precautions and risks:
During preparation, the level in the pulp container (6) should be monitored to prevent the cover pulp outlet
(2) from clogging. Such clogging could result in an imbalance in the basket assembly (5) and thus a risk of
damaging the machine.
The quantity of products to be processed before reaching the maximum filling level in the container (6)
varies according to the products being processed.
If during preparation an imbalance should occur well before the pulp container is full, it is sometimes
appropriate to continue adding food for the imbalance to be cleared.
But if the imbalance continues, the machine must be stopped and the basket assembly (5) cleaned. Certain
products are liable to clog or block the sieve holes, in which case the basket assembly (5) should be
cleaned more frequently.
MAINTENANCE
Before carrying out any work on the juice extractor, the machine must in all cases be unplugged from the
mains power supply and the motor start capacitor discharged: