Problem
After entering an
access code to
unlock the lock, the
yellow dot is flashing
and there is a delay
before unlock.
Inside Schlage Button
is flashing but no
alarm is sounding.
3 Red
when
Outside Schlage
Button is pressed.
Pressing Outside
Schlage button when
deadbolt is unlocked
does not cause
deadbolt to relock.
Deadbolt will not
extend or retract as
expected.
Deadbolt requires
two attempts to lock
or unlock.
The bolt was
operating smoothly,
but now is not.
* These features are not available using manual programming if your lock has been paired
using the Schlage Sense mobile application.
Sounds
Lights
Several
Outside
beeps
yellow dot
flashing
Inside
Schlage
Button
flashes
every 5
minutes
3 Red
1 long
1 Red
beep
Green
Solution
Battery is low and should be replaced.
See Replacing the Batteries on page
6.
Battery is critical and must be replaced.
See Replacing the Batteries on page
6.
The 1-Touch Locking feature is not
enabled. See lock settings in Schlage
Sense app.
If you do not want to enable Lock &
Leave, then enter a valid access code to
lock the door.
Adjust bolt/frame alignment. Browse to
answers.schlage.com for help.
Deadbolt/frame alignment is marginal.
Adjust door/frame for best operation.
Browse to answers.schlage.com for help.
The bolt has become soiled. Clean with
mild detergent and warm water.
The strike has become worn. Flip
the strike over for continued smooth
operation.
13