MarelliMotori MEC-100 Manuel De L'utilisateur page 61

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.13.2. EMC
Immunity
Immunity: Reference standard EN 61000-6-2 (2005)
Test specifications
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
(+)
Apparatus does not contain devices susceptible to magnetic fields
The compatibility test results according to the 89/336 EEC and 2004/108 EC Directives and subsequent amendments.
2.13.3. Climatic
Reference standard DNV No. 2.4
Test specifications
Class: C (-25°C / +55°C)
Standard IEC 60068-2-2
Class: C (-25°C / +55°C)
Standard IEC 60068-2-2
Class: C (-25°C / +55°C / 100% R.H.)
Standard IEC 60068-2-30
2.13.4. Vibrations
Reference standard DNV No. 2.4
Test specifications
Class: B
Standard IEC 60068-2-6
2.13.5. Shock & Bump
Test specifications
IEC 60255-21-2
IEC 60068-2-27
2.14. AGENCY RECOGNITION
DNV (Reference standard DNV No. 2.4
Application
Temperature
Humidity
Vibration
EMC
Enclosure
Certificate No. A-12190
963857137_M
Environmental Phenomena
Electrostatic discharge
Radiated electromagnetic field
Electrical fast transients
Surge
Injected currents
Power frequency magnetic field
Dips/short interruptions
2006
Environmental Phenomena
Dry Heat
Cold
Damp Heat
2006
Environmental Phenomena
Vibration
Environmental Phenomena
Shock response test (Class 2
Shock withstand test (Class 22
Bump test (Class 22
Shock response test (+/-5g, 10ms, 10*3)
2006 )
C
B
B
A
IP00
10g, 11ms, 3*3)
30g, 11ms, 3*3)
20g, 16ms, 1000*3)
MEC-100 – Marelli Motori
Result
Complies
Complies
Complies
Complies
Complies
N.A. (+)
Complies
Result
Complies
Complies
Complies
Result
Complies
Result
Complies
Complies
61

Publicité

Table des Matières
loading

Table des Matières