13. Safety Inspection
All inspections and repairing must be written down in the maintenance diagram. This counts not only for your own
inspections but also for inspections which are carried out by your authorized pewag distributor or recognized
mechanical repair center. When the clamp is handed in for maintenance and inspection you always must provide
the maintenance diagram.
Defective Lifting Clamps
When a form of wear or damage is indicated, you must take the following measures.
• Take the lifting clamp out of use (note the date of failure of the lifting clamp)
• Try to recover the cause of the failure, for example (complete list is available in Chapter 10): These claims do not
fall under the guarantee! To guarantee the security of you and your colleagues you are obliged to follow up this
procedure
• Return your lifting clamp (with the maintenance history) to your authorized pewag distributor or recognized
mechanical repair center
• If the lifting clamp has been revised/repaired by your distributor or recognized mechanical repair center, you can
safely use your clamp again. Please note this date in your maintenance chart (see page 25)
14. Inspection Schedule
E
Months
Years
Safety inspections by
your own inspector
Maintenance by an
official pewag distributor
Revision by an official
pewag distributor
12
4
8
12
16
20
1
2
24
28
32
36
40
3
44
48
52
56
60
4
5