Manual Bypass Operation
Contacts on Power/Battery Module
WARNING! High Voltage!
Risk of electrical shock!
Due to the presence of high voltage internal batteries,
even without AC present, these contacts
Do not let these contacts touch any surface!
Specifications
The models listed below include a power module, one or two battery modules, and a PDU module.
Model Information
Model # (S)
Input
Input Connection Type
Input Voltage Range
Module Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor (Full Load)
Efficiency (Full Load/On-Line)
Power Module Circuit Breaker
Battery Model
Output
VA
Watts (Power Factor: 0.9)
Output connection Type
Waveform (On-Line)
Waveform (On-Battery)
Output Voltage (RMS)
Output Frequency
Voltage Regulation
Max. Harmonic Distortion (Linear Full Load)
Max. Harmonic Distortion (NonLinear Full Load)
Overload Capabilities
Short Circuit Capability
Crest Factor
Operation
On-Line Transfer Time (Line to Battery, Battery to Line)
Audible Noise (Full Load @ 1m)
Indicators
Communications
Physical Specifications
Unit Dimensions (H x W x D)
Power Module
PDU Module
Shipping Weight
Shipping Weight
Power Module
PDU Module
201102160 93-2897.indb 11
(for power module maintenance or replacement) (continued)
High Voltage Warnings
are live!
A
A
8kVA
Anderson Power Connector 75A (3 pole)
156~280V Single Phase
200/208/220/230/240V AC
50/60Hz (40~70Hz)
46.0/44.2/41.8/40.0/38.3 (Max.)
<200A
>0.98
90%
N/A
BP240V10RT-3U; 20 x 12V9Ah
8000
7200
Anderson Power Connector 75A (3 pole)
Sinewave
Sinewave
200/208(default)/220/230/240Vac (Single Phase)
50/60Hz ± 0.05Hz
±2%
<2%
<3%
105% ( Continuous ), 106%-125% (1 Minute),
126%-150% ( 30 sec. ), >150% ( Immediate )
2.7:1
0 ms.
60dBA
Includes an LCD Display and LEDs (I/P (input), BATTERY, AC/DC, BYPASS DC/AC, O/P (Output)).
Includes an RS-232, a parallel connector , USB connector, a EPO connector and an accessory slot.
25.82 x 17.5 x 5.14 in. [ 665.8 x 444.5 x 130.5 mm]
20.54 x 6.96 x 4.49 in. [ 521.8 x 176.8 x 114 mm]
66 Ib. [30 kg.]
Contacts on Detachable PDU
WARNING! High voltage!
Risk of electrical shock!
If AC is present and Bypass Switch is set to "Bypass",
these contacts
Do not let these contacts touch any surface!
10kVA
Anderson Power Connector 75A (3 pole)
156~280V Single Phase
200/208/220/230/240V AC
50/60Hz (40~70Hz)
56.1/54.0/51.0/48.8/46.8 (Max.)
<200A
>0.98
90%
N/A
BP240V10RT-3U; 20 x 12V9Ah
10000
9000
Anderson Power Connector 75A (3 pole)
Sinewave
Sinewave
200/208(default)/220/230/240Vac (Single Phase)
50/60Hz ± 0.05Hz
±2%
<2%
<3%
105% ( Continuous ), 106%-125% (1 Minute),
126%-150% ( 30 sec. ), >150% ( Immediate )
2.7:1
0 ms.
60dBA
25.82 x 17.5 x 5.14 in. [ 665.8 x 444.5 x 130.5 mm]
20.54 x 6.96 x 4.49 in. [ 521.8 x 176.8 x 114 mm]
66 Ib. [30 kg.]
11
are live!
B
B