4. Use and operation

The Simco-Ion BlowION is used to neutralize electrostatically charged products and/or surfaces
up to a distance of 1 m.
The BlowION consists of a series of fans in an aluminium casing with an anti-static bar fitted on
the outflow opening. The blower produces an air flow that is rich in positive and negative ions.
When this air flow is pointed to an electrostatically charged product / surface, ions will be
exchanged. This causes the product/material to be neutralized.
The BlowION can be supplied with an optional air inlet filter and fan speed control. The air flow
strength is adjustable. The BlowION can be supplied with an air inlet filter.

5. Technical specifications

Mains voltage
Rated mains current AC
Maximum mains current AC
Frequency
Operating voltage of anti-static
bar
Ambient temperature
Operating conditions
Materials used
Mains connection
Data per
effective length
Options:
BlowION_UM_9752060910_NL_D_GB_F_V2_3
100 – 240 V AC
2 A / 115 V, 1 A / 230 V
3.5 A (100 V)
50/60 Hz
4 kV AC, max. 0.7 mA from emitter point to earth
0 - 50 C
Industrial
Aluminium, steel, brass, stainless steel
ABS, PBT/ABS, glass fibre
Power cable 2 m via euro connector IEC-320
Eff. Length/
Weight
Tot. Length
(kg)
(mm)
520/731
11.0
680/891
12.5
840/1051
14.0
1000/1211
15.5
1160/1371
17.5
1320/1531
19.0
1480/1691
20.5
1640/1851
22.0
1800/2011
23.5
1960/2171
25.0
1) Noise level measured at a distance of 100 cm.
Air filter, PU, 30 pores per inch (coarse filter >10 µm)
Hinged mounting set
Fan speed control (ex-works)
Air
1)
Noise level (dB)
Displace-
at
ment
Low / High speed
3
(m
/h)
750
49 / 60 dB
1000
49 / 60 dB
1250
50 / 61 dB
1500
50 / 61 dB
1750
50 / 61 dB
2000
51 / 62 dB
2250
51 / 62 dB
2500
51 / 62 dB
2750
52 / 63 dB
3000
52 / 63 dB
GB