9.3. Air filter replacement / cleaning

1. Remove the filter's strips by removing the knurled screws.
2. Remove the filter cloth behind the grid by tilting the grid.
3. If necessary, clean the filter cloth using a vacuum cleaner and/or compressed air. The used
PU filters may be washed in water (allow them to dry properly).
4. Insert a clean filter of the correct length behind the grid.
5. Resnap the grid onto the blower's casing.
6. Remount the strip with the knurled screws and check that the entire air inlet is covered by
the filter cloth.

10. Faults

Problem
Red LED indicator lights up
(high voltage fault)
Red and/or green LED
flashes
Both LED indicators are off
Poor ionisation
Insufficient air flow
Table 1 faults
If the solution does not solve the problem, please submit the BlowION for repair. Please contact
Simco-Ion or a regional agent.

11. Repair

The BlowION does not contain any parts which can be repaired or replaced by the user.
BlowION_UM_9752060910_NL_D_GB_F_V2_3
Cause
Short circuit in the anti-static
bar
Short circuit in the anti-static
bar
No mains voltage present
Fouled emitter points
Filter fouled / clogged
Air flow
Speed control set too low
Remedy
Eliminate short circuit
Eliminate short circuit
Supply blower with mains
voltage
Clean emitter points.
Clean or replace filter
Air flow
Set the speed control to a
higher speed (Chapter 7)