LED Reading
E90
Water temperature too low
E94
Water temperature too high
E95
E96
Dry-fi re Protection
E97
Water temperature sensor broken • Contact Intex Service Center.
E99
After 72 hours of continuous
heating operation, the pump will
hibernate automatically. The rapid
END
heating and water fi ltration
functions are disabled.
S AVE THESE INSTRUCTIONS
(295IO) SPA ENGLISH 7.5" X 10.3" PANTONE 295U 11/06/2017
LED CODE CHART
CAUSE
• Turn off and unplug the control unit.
• Ensure the outlet cover grid is clean and free
from obstructions.
• Clean or replace the cartridge, see
Maintenance and Storage section.
No water fl ow
• Ensure the in/outlet connections on the spa tub
and fi lter pump are not blocked.
• Keep the spa water properly sanitized to
ensure a clean and unclogged fi lter cartridge.
• If problem persists, contact Intex Service
Center.
• If the ambient temperature is below 4°C (39°F),
we recommend not to use the spa.
• Turn off and unplug the control unit, add some
warm water to raise the spa water temperature
above 5°C (41°F), then press the
heat up the water to the desired temperature.
• If problem persists, contact Intex Service
center.
• Turn off and unplug the control unit. When the
water has cooled down, plug the RCD and
restart all over again.
• Turn the heater off, then press the fi lter and
bubble buttons to lower the water temperature.
• If problem persists, contact Intex Service
Center.
• Turn off and unplug the control unit, use the
cap to stop the water from fl owing out of the
tub, disassemble and drain out the control unit.
System Error
Reassemble the control unit back to the tub.
Plug the RCD and restart all over again.
• If problem persists, contact Intex Service
Center.
• Contact Intex Service Center.
• Press the
fi lter pump.
English
SOLUTION
button to
button to re-active the
Page 14
295
A