Section 5 − Maintenance; Maintenance Schedule; Cleaning Extractor Tray - Miller Filtair 250M Mode D'emploi

Masquer les pouces Voir aussi pour Filtair 250M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5-1. Maintenance Schedule

n = Check
* To be done by Factory Authorized Service Agent
Each
Use
n Extraction System
Every
3
Months
n l Damaged Or
Unreadable Labels
Every
OR
6
Months
~ Top Covers

5-2. Cleaning Extractor Tray

250M Model Shown
1/2 in.
SECTION 5 − MAINTENANCE
Z = Change
~ = Clean
~ Extractor Tray
Tools Needed:
.
Maintain more often during severe conditions.
l = Replace
!
!
!
!
1
.
1
Remove hardware securing tray to
extractor side brackets.
Lower tray from hood. Clean out
debris from tray.
Reinstall and secure tray to side
brackets.
Vacuum top of hood.
Reference
See Section
5-2
Do not operate unit without
extractor tray.
Do not breathe the particles
collected by the fume extrac-
tor. Wear approved safety
equipment
(respirator,
gloves, long sleeve shirt)
when servicing filter and
spark guard. Dispose of
used element and collected
particles according to local,
state, and federal require-
ments.
Read and understand the
Material Safety Data Sheets
(MSDSs) and the manufac-
turer's instructions for met-
als, consumables, coatings,
cleaners, and degreasers.
Use lifting aid or two persons
to remove extractor tray.
Particle tray is heavy when
full.
See Section 4-3B for installa-
tion hardware torque values.
Extractor Tray
Ref. 300 963−7B / Ref. 300 963−2A
OM-254 497 Page 21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Filtair 350s

Table des Matières