8
IOM
IOM
WHEN THIS FURNACE IS INSTALLED IN A STORAGE GARAGE, IT MUST BE INSTALLED
SO THE BURNERS AND IGNITION SOURCE ARE LOCATED NO LESS THAN 18" (457 mm)
ABOVE THE FLOOR TO PREVENT THE RISK OF IGNITING FLAMMABLE VAPORS WHICH
THE FURNACE MUST BE LOCATED OR PROTECTED TO AVOID PHYSICAL DAMAGE BY
FAILURE TO HEED THESE WARNINGS CAN CAUSE A FIRE OR EXPLOSION, RESULTING
FIGURE 1 - FURNACE DIMENSIONS
0"
0"
NOTES:
S - Service clearance 24 inches (610mm) or more.
C - Combustible floor (but not carpet or non-ceramic tile).
All models approved for closet installation.
W415-2308 / B / 11.04.19
!
MAY BE PRESENT IN THE GARAGE.
IN PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
Plenum
1/2" (13mm)
on all sides
0"
0"
Top
0"
*24" (610mm) REQUIRED FOR SERVICE
**SUPPLY AIR OUTLET / 1/2" (13mm) RETURN AIR INLET
*** CERTIFIED FOR CLOSET INSTALATION ON COMBUSTIBLE FLOORING.
WARNING
!
VEHICLES.
TABLE A - FURNACE DIMENSIONS
INPUT
Width
Depth
Height
K/Btu/hr
A
B
40
17 1/2"
60
(445mm)
80-3
29 1/2"
80-4
(749mm)
(864mm)
22 1/2"
100
(572mm)
120
TABLE B - MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
UPFLOW
TOP
PLENUM TOP
1/2" (13mm)
FRONT
BACK
SIDES
BOTTOM
FLUE PIPE
ENCLOSURE
CLOSET
H3.6A
Supply Air
Return Air
C
(F x G)
16 1/2" x 19 5/8"
(419mm x 499mm)
14" x 23"
34"
(356mm x 584mm)
22 1/2" x 19 3/8"
(572mm x 492mm)
H12.6.12A
DOWNFLOW
HORIZONTAL
0
0
0
1/2" (13mm)
0*
0*
0
0
0
0
0***
0
0
0
CLOSET
H12.11.2
(D x E)
0
0*
0
0**
0
0
CLOSET