8.4
Assignment of the data bits
In one transmission cycle the following data is transferred in data triples:
E1
E2
E3 D16 D15 D14 D13 D12 D11 D10 D9
extension
bits
(static 0)
Additional information bits:
O = overflow bit (is set with the values 7FFF and 8000 hex., otherwise 0)
V = valid bit (is set with a valid value)
8.5
Code value representation using the data bits D16...D1
The ID value is represented as a signed 16-bit number.
Range
Value range
Message range
Value 0 = no ID tag in the reading range or ID tag not detected
8.6
Additional functions to the AS-i profile 7.4
(Applies only to read/write heads)
Function, description
Read ID string
reading AS-i slave information
Read diagnosis string
reading statistics via read/write processes
Read parameter string
reading back data from the ID tag
Write parameter string
writing data on the ID tag
requesting data from the ID tag
● = function implemented
Description, examples and software for various controllers at:
→ Service → Download
www.ifm.com
D8
D7
user data bits
Decimal
from
to
0
32767
-1
-32768
D6
D5
D4
D3
D2
D1
Hex
from
to
0
7FFF
FFFF
8000
DTA100 DTA200 DTA300
●
●
●
●
–
●
●
●
–
●
O
V
UK
●
●
●
●
●
21