Maintenance; Maintenance Work - Kessel SonicControl Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
7

Maintenance

7.1

Maintenance work

DANGER
To clean the sensor, the control unit must be disconnected from the mains (all-pole break).
The sensor must be cleaned with warm/hot water with each disposal.
In the case of the KESSEL EasyClean Auto Mix, Mix & Pump and Auto Mix & Pump grease separators, the cleaning of
the sensor can be omitted until the next maintenance, if the separator is cleaned with warm water. If necessary (heavy
soiling of the sensor due to highly hardening grease), carry out cleaning with each disposal
Check the connection cables and sensor for damage.
In case of identifiable damage, shut down the sensor immediately and have it replaced by an electrically skilled person.
After emptying, fill the separator with clean water.
|2.5 SonicControl calibration|
Repeat the calibration (
016-283
) if the sensor has been twisted or moved.