BURNING WOOD IN A SMOKE CONTROL AREA - continued
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur. Refuelling
must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable
period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left
open except as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be operated
with air controls, appliance dampers or door left open except as directed in the instructions.
Fuel Overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke
SE Cleanheat - SMOKE EXEMPTION MODIFICATION
Smoke exempt models are factory fitted with a air stop
on the air control slider: The adjust control to smoke
control settings place Allen key on bolt in the air
intake ( at the rear of the stove ensuring that the air
control is limited to
● No limit is needed for Christon 550
● Reduce travel to 2.5 cm/50% for Christon 750
SOLID FUEL - COAL - SMOKELESS COAL
SMOKELESS COAL, HOUSE COAL AND PETROLEUM COKE ARE NOT
SUITABLE FOR USE ON THIS STOVE; ITS USE WILL INVALIDATE THE
SOLID SMOKELESS FUELS - Christon 550/750 models are NOT suitable for use with smokeless fuels and have not been
tested to the relevant European standard. Only use wood for these stoves.