1 - TECHNICAL SPECIFICATIONS

Supply voltage:
Working:
Time remaining from when "Battery Low" symbol:
Backlight display:
Type of action, disconnect and device:
Type of output:
Software:
Nominal pulse voltage:
Wire section to relay terminals:
Input (telephone programmer):
Wire section to telephone programmer input terminals:
Insulation:
Protection degree:
Pollution rating:
Ambient temperature display range:
Ambient temperature indicator resolution:
Adjustment temperature range (t1/t2/t3):
Setting temperature resolution:
Temperature correction (Offset):
Frost protection temperature (t ):
Methods to adjust the temperature:
-
DIFFERENTIAL (default)
-
PROPORTIONAL
Thermal gradient:
Operating temperature limits:
Storing temperature limits:
Reference standard for CE mark:
Note:
when room temperature flashes, display scale (-5°C or +39°C) has been exceeded.
Err
indica
tes that heat control activity has been suspended due to probe error.
N° 2 alkaline 1,5 V type AA (LR6)
2 years
1 month approx.
Only for models with this option
1/ B / U / Electronic
Relay with single-pole changeover contact,
voltage free, NO / COM / NC - max 8(2)A/250 V ac
Class A
4 kV
2
2
0,75 mm ÷ 2,5 mm
for NO contact, zero potential
2
2
0,5 mm ÷ 1,5 mm
Class II
IP 30
Normal
- 5 °C ÷ +39 °C
0,1 °C
+ 5 °C ÷ +39 °C
0,1 °C
Settable from -1,9 °C to +1,9 °C
Settable from +4 °C to +12 °C (default 5 °C)
Settable from 0,2 °C to 2 °C (default 0,6 °C)
Cycle settings are 7-10-15-20 minutes (default 10')
max 1°K / 15 min
- 5 °C ÷ +50 °C
-10 °C ÷+ 65 °C
LVD / EMC
EN60730-2-7 EN60730-2-9
29