Press the power-on button to switch on the appliance (Fig. 6).
Note: If you plug in the appliance after you have pressed the power-on button, the steriliser starts to heat
up immediately.
SCF287/SCF286
The sterilising light lights up to indicate that the appliance starts operating.
,
When the sterilisation process is finished, the ready light goes on. After 3 minutes the ready
,
light goes out to indicate that you can now safely open the steriliser.
SCF285/SCF284
The sterilising light lights up to indicate that the appliance starts operating.
,
When the sterilisation process is finished, the appliance switches off automatically.
,
6
Remove the lid.
Wait until the appliance has cooled down before you remove the lid.
Be careful, hot steam may come out of the steriliser.
7
Remove the bottles and other items from the basket. Use the tongs to remove the smaller items.
Be careful, the sterilised items may still be hot.
Note: Make sure you wash your hands thoroughly before you touch sterilised items.
8
Unplug the appliance and wait until the appliance has cooled down completely.
9
Pour out any remaining water from the water reservoir and wipe the water reservoir dry.
Note: The appliance does not work for 10 minutes after a sterilising cycle; it needs to cool down first.
Cleaning
Do not use abrasive or aggressive cleaning agents (e.g. bleach) or a scouring pad to clean
this appliance.
Never immerse the base, the mains cord or the mains plug in water or any other liquid.
Note: The steriliser is not dishwasher-proof. The baskets and the lid can be cleaned with hot water and
some washing-up liquid.
1
Always unplug the appliance and let it cool down before you clean it.
2
Clean the base with a moist cloth.
3
Clean the other parts in hot water with some washing-up liquid.
Note: After cleaning, store the steriliser in a clean, dry place.
Descaling
When you use the steriliser, small spots may appear on the heating element in the base. This is scale
that is building up. The harder the water, the faster scale builds up. Descale the steriliser at least
every 1 or 2 weeks to ensure that it continues to work effectively.
1
Pour 80ml/2.7oz of white vinegar (5% acetic acid) and 20ml/0.7oz of water into the water
reservoir.
2
Leave the solution in the water reservoir until the scale has resolved.
3
Empty the water reservoir, thoroughly rinse it and wipe the base with a damp cloth.