Clearances to Combustibles
Parallel
Wall Installation
WARNING ‐ INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER
Single Wall Chimney
Connector Unprotected
Surface with side shields
Double Wall Chimney
Connector Unprotected
Surface with side shields
Notes for this unit: The product may differ slightly from the diagrams. The clearances are the minimum for this unit and may
need to be increased for blower installation or to have proper ventilation clearances.
Observe all ventilation manufacturer clearances and local codes.
INSTALLATION
Chimney
Unit to Side
Connector
Wall
to Side
Wall
A
B
in (cm)
in (cm)
19
30
(48.3)
(76.2)
19
30
(48.3)
(76.2)
F
Corner Installation
Chimney
Unit to
Connector to
Rear Wall
Rear Wall
C
D
in (cm)
in (cm)
12
6
(30.5)
(15.2)
12
6
(30.5)
(15.2)
Chimney
Unit to
Connector
Corner
to Corner
E
F
in (cm)
in (cm)
5
17
(12.7)
(43.2)
5
17
(12.7)
(43.2)
Page | 7