2
Screw on the door contact switch behind the com-
bustion chamber door on the right side.
First, push the connection cable through the instal-
lation opening.
Door contact switch
3
After the installation, check to make sure that the
door contact switch works perfectly when the com-
bustion chamber door is closed.
→ The combustion chamber door must close
perfectly.
→ The door contact switch must click audibly when
the door opens.
→ If necessary, adjust the depth of the door contact
switch.
20
4
Push the temperature sensor into the sensor pocket
on top of the heating jacket and screw tight with the
sensor sleeve and the union nut.
Temperature sensor
Union nut
5
Connect the sensor cable to the back or to the side
of the unit down to the wood storage compartment.
6
Push the cable of the power supply through the
grommet in the back panel at the bottom.
Sensor sleeve