TB20AM
TABLE OF THE VOLTAGES AT WHICH THE BATTERY SAVER COMES INTO ACTION
BATTERY SAV ER VO LTAGE
VOLTAGE
12V
24V
b) Amperometric protection in case the compressor should fail to start up .
This generally happens when the pressures do not have time enough to balance themselves again.
Should this kind of protection come into action, the compressor will carry out a 1 minute pause and will then
start up again automatically.
Wiring connections
The wiring connection must be made complying with the following instructions:
1) Feed the refrigerator with direct current coming from a battery (12 or 24 Volt.).
Do not feed it with equipment which does not provide the maximum guarantee of continuity, such as
transformers or other instruments.
2) Use cables having a suitable cross section (see the table) to feed the refrigerator. If possible, they should
be without any joints on the leads which could cause voltage drops.
NOTE. Using cables of a wrong cross section could stop the compressor even if the battery is charged.
C AB LE C ROSS
m m
2
S EC TIONS
2,5
4
6
10
3) Any switches must have a break load of not less than 20 A.
4) Make sure the polarity is right (+ Red / - Black).
5) The refrigerator is protected by a 16 A fuse.
6) To make the connection use the connector provided with the device.
US E
TU R N I N G O N
The fridge is turned on by pressing the switch located on the side.
S E T TI N G TH E I N S I D E TE M PE R ATU R E
The fridge temperature can be adjusted by turning the thermostat knob.
Turning it in a clockwise direction lowers the temperature; a coin can be used to make the adjustments.

CO LD ACCU M U L ATO R

It is provided with liquid containers which allow you to store a set amount of cold.
Cold storage takes place automatically during the first 2 or 4 hours of operation with the thermostat in
medium position.
TB20AM_04-06-2020
STOP
START UP AGAIN
Volt 10,1
Volt 22,3
M AX IMUM LE NGTH I N ME TR ES
12 V
2,5
4
6
10
Volt 11,4
Volt 23,7
24 V
5
8
12
20