6 6
6Safety6Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal pressu-
res.
Installation6Instructions
• The fitting must be installed, flushed and tested after
the valid norms.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Technical6Data
This6mixer6series-produced6with6EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
4
English
Symbol6description
®
6(flow
®
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Assembly6see6page632
Do not use silicone containing acetic acid!
Dimensions6(see page 31)
Flow6diagram6
(see page 31)
with EcoSmart
®
without EcoSmart
®
Spare6parts6(see page 34)
XXX = C olors
000 =
chrome plated
090 =
chrome plated/gold plated
Special6accessories
special tool (58085000) order as an extra
Installation kit order as an extra
Operation6(see page 35)
Cleaning6recommendations,6
see6enclosed6brochure.
Test6certificate6(see page 36)