Nivotemp NT 61, NT 61-HT, NT 63, NT 63-
LTD/Nivovent NV 71, NV 73
1.2 Standard pin assignment NV 71
Plug connection

Dimensions

Number of pins
DIN EN
Max. voltage
IP rating
Cable fitting
Max. Number of
contacts
Level/temp. contacts
Level contacts only
*Max. 48 VAC/ VDC for change-over contact. **with IP67 cable box attached. Other plug connections available upon request
24
Bühler Technologies GmbH
M3
3-pin + PE
175301-803
175201-804
230 VAC / DC*
230 VAC / DC*
IP65
PG 11
1 x K10 / 1 x TK
3 x K10 / 1 x TK
- / -
2 x K10 / 2 x TM
- / -
1 x W11 / 1 x TK
1 x W11 / 2 x TM
2 x K10
1 x W11
S6
M12 (base)
6-pin + PE
61076-2-101
30 VDC
IP65
M20 x 1.5
1 x K10 / 1 x TK
4 x K10
2 x K10
2 x W11
1 x W11
2xM12 (base)
4-pin
4-pin / 4-pin
61076-2-101
30 VDC
IP67**
IP67**
3 x K10 / 1 x TK
- / -
2 x K10 / 2 x TM
- / -
1 x W11 / 1 x TK
1 x W11 / 2 x TM
4 x K10
2 x W11