SAMPLES OF ALLOWABLE PLENUM/DUCTING ARRANGEMENTS
EN
"ADD ON"
FURNACE
6.6
EMBER STOP
○
For installations on combustible fl ooring an ember stop protective fl oor covering must be installed.
○
An ember stop of minimum 0.015" (0.4mm) thick sheet steel extending 18" (457mm) in front of fi rebox door
to 2" (76mm) behind the cleanout of the chimney. The ember stop width must protrude a minimum of 8"
(203mm) from both sides of the furnace.
○
Carpet or other fl oor covering shall be removed before placement of ember stop sheet.
○
Refer to Section 7.1 of CAN/CSA-B365-10 for complete details of fl oor protection.