4.4
CONFIGURING CHMF150/200 AS LEFT OR RIGHT "RETURN AIR" (RA)
The CHMF150/200 can be installed upstream with
EN
the return air, (also supply air from pre existing
furnace "add on" confi guration), entering from
the left or right hand sides of the furnace. The
CHMF150/200 comes confi gured for left side RA.
STEP #1:
Remove all screws holding
side panels.
4.5
MOUNT MAIN ELECTRICAL HARNESS TO FURNACE
LEFT RA
LEFT RA
W415-1506 / C / 02.15.18
RETURN AIR
PLENUM
LEFT AND RIGHT HAND SIDE PANELS ARE REVERSIBLE
STEP #2:
Tilt side panels outwards from
top and pull up diagonally.
Attach the electrical mounting
bracket with fasteners supplied.
Line up the bracket mounting
holes with the dimple in the
furnace side panel.
Note that in both left and right
RA confi gurations the mounting
bracket goes closest to the rear of
the furnace.
Secure the electric harness upper
portion to the furnace side panel,
and the lower portion to the
installed bracket.
RETURN AIR
PLENUM
STEP #3:
Switch panels to opposite
sides and reverse process.
RIGHT RA
RIGHT RA