HDA 5500 for HLB 1000 and CS 1000
7.2 Overview of basic settings menu
Menu point
Setting
Device:
When HLB 1000 is selected
Allocation switching output 1 (S.S.1)
Switching function switching output 1 (S.M.1)
Switching direction switching output 1 (S.d.1)
Switch on delay switching output 1 (T.on1)
Time, in seconds, which must elapse once the particular switch
point has been reached or exceeded in order for a switching
function to occur.
Switch-off delay switching output 1 (T.oF1)
Time, in seconds, which must elapse once the value has fallen
below the particular switch-back point in order for a switching
function to occur.
Switching function switching output 2 (S.S.2)
Similar to switching output 1 (see above), and likewise for:
•
Switching mode (S.M.2)
•
Switching direction (S.d.2)
•
Switch-on delay (T.on.2)
•
Switch-off delay (T.oF.2)
Device selected to display the values measured
by the HLB 1000 connected
Device selected to display the values measured
by the CS 1000 connected
Switching output 1 allocated to the signal
of rel. change in viscosity
Switching output 1 allocated to the signal
of rel. change in dielectric constant
Switching output 1 allocated to the signal
of rel. humidity
Switching output 1 allocated to the signal
of temperature
Switching output 1 set to switch point and
hysteresis mode
Switching output 1 set to switching window mode
Relay activated
Relay deactivated
Setting range
Default setting
HLB,
HLB
CS
r.ViS.
r.ViS.
r.diE.
r.HuM.
TEMP.
SP
SP
Win
on
on
oFF
0..99.99 s
0
0..99.99 s
0
r.ViS.
r.ViS.
r.diE.
SP
r.HuM.
on
TEMP.
0
SP
0
Win
on
oFF
0..99.99 s
0..99.99 s
- 8 -